Instrument |
Instrument Size |
260 x 140 x76 mm |
6,3" x 5,5" 3,0" |
Instrument Weight |
0,75 kg |
1,6 lb. |
Power Supply |
100 - 240 V
50/60 Hz 0,7 A
|
100 - 240 V
50/60 Hz 0,7 A |
Operating Temperature |
0 - 40° |
32 - 100° F |
Humidity |
90 % non condensing |
|
|
Force |
Range |
0 - 89 N |
0- 20 lb |
Resolution |
0,003 N |
0,0007 lb |
Instrument Display Readability |
0,44 N |
0,1 lb |
Computer Results Readability |
0,004 N |
0,001 lb |
|
|
Displacement |
Range |
35,6 mm |
1,4" |
Resolution |
0,013 mm |
0,0005" |
Accuracy |
0,025 mm |
0,001" |
Linearity |
0,025 mm |
0,001" |
Computer Results Readability |
0,025 mm |
0,001" |
Actuator Forward Speed |
4,0 mm/s |
0,16 ips |
Actuator Reverse Speed |
6,4 mm/s |
0,25 ips |
|
|
Locktime |
Range |
0,3 ms - 14,5 ms |
|
Resolution |
0,1 ms |
|
Accuracy |
0,1 ms |
|
Readability |
0,1 ms |
|
|
|
Compression Spring Test |
Spring Length Range |
15 -76 mm * |
0,6 - 3" * |
Spring Inside Diameter |
3,2 mm min* |
0,126" * |
Spring Testing Force |
0 - 89 N |
0 - 20 lb |
* Springs of other diametres and length can be tested with other adapters |
|
|
Software Requirements |
Processor |
486 or Pentium |
Free Memmory Space |
min. 1 Mb |
Operating System |
Windows 3.2 |
|
Windows VISTA®, Windows7® oder Windows10®
|
|
|
Monitor |
min. 640 x 480 |
Misc. |
3,5" Floppy Disc or CD-ROM |
|